Both assays are time intensive, highly variable, and limited in throughput as they require expert visual analysis. Thus, a novel, quantitative cell-based in vitro measles infectivity assay ( Fig. 1) for quantifying the infectivity of MV in standard 96-well microtiter plates was developed. The fluorescence-based assay uses a recombinant Edmonston-derived laboratory-adapted MV expressing enhanced green fluorescent protein (MVeGFP) [27] and is quantitated using automated image analysis. The assay has a wide dynamic range (≥2.0 orders of magnitude), low variability (Relative Standard Deviations, RSDs ≤30%, as measured through the
thousands of control formulations across the screening campaign), and short duration (<4 days). Two additional measures not typically used during measles infection buy BI 2536 were implemented to optimize this assay for the HT screening process. First, fusion
inhibitory protein (FIP) was used to prevent cell-to-cell spread and therefore secondary infections, and thereby increase the dynamic range of the assay. In a typical MV infection, neighboring cells fuse to form multinucleated syncytia, which markedly vary in size, shape, brightness and sharpness. Physical overlaps between syncytia create an upper limit on dynamic range, and their non-uniform appearance makes accurate C59 wnt cell line quantification challenging, especially when using automated image analysis. FIP prevents syncytia formation through an unknown molecular mechanism [30]. When FIP is added shortly after the initial infection, fluorescent infectious centers remain discrete, single objects of uniform size and shape (Fig. 1a), each representing a single cell infected by MVeGFP. Second, Calpain the relatively low titer of MV in typical cell culture (∼106 plaque-forming units) plus the additional reduction of virus concentration as a result of its dilution into formulation places limits on the upper bound of detection. In order to address these challenges, we introduced a “spinoculation” step. Centrifugation of inoculated cell monolayers at low speed has been shown to enhance the detection of viable virus (e.g. for HIV [31]),
presumably by bringing infectious particles into close contact with the cells, thereby facilitating infection. Addition of FIP to the viral inoculum prior to centrifugation completely eliminated infection, suggesting that the molecular mechanism of viral entry is not affected (results not shown). Spinoculation, however, causes an apparent increase in viral titer of approximately 0.5 log10 increasing the upper end of the range (Fig. 1b). This apparent increase in titer reduces consumption of virus during HT screening and allows for greater dilution of virus stock into formulation. FIP and spinoculation increase the dynamic range of the assay approximately 2.5-fold from 1.8 logs (∼5 to ∼300 object counts, data not shown) to ∼2.